dc.description | Texto completo. Acesso restrito. p. 159–163 | pt_BR |
dc.description.abstract | In the present paper the use of a MSFIA system for determination of mercury in rice by cold vapour
atomic fluorescence spectrometry (CV AFS) is proposed. The sample digestion is performed in a microwave
oven using nitric acid and hydrogen peroxide. The experimental conditions for vapour generation
were determined using a full two-level factorial design involving the following factors: nitric acid and tin
chloride concentrations and sample flow rate. Employing the conditions optimised, the method allows
the determination of mercury using the external calibration technique with aqueous standards. The
reached limits of detection and quantification were 0.48 and 1.61 ng g 1 respectively, and the precision
(as relative standard deviation) was 3.28% and 1.56% for rice samples with a mercury content of 3.63 and
5.81 ng g 1, respectively. The method accuracy was confirmed analysing a certified reference material of
rice flour furnished by National Institute of Standard and Technology. The interference of nitrous acid and
nitrous oxides are removed using potassium dichromate. The method was applied to mercury determination
in twelve rice samples acquired in Palma de Mallorca (Spain) between the months of January
and April of 2012. The mercury content found varied from 2.15 to 7.25 ng g 1. These results agree with
those reported by others authors. | pt_BR |
dc.language.iso | en | pt_BR |
dc.publisher | Food Chemistry | pt_BR |
dc.source | http://dx.doi.org/10.1016/j.foodchem.2012.10.019 | pt_BR |
dc.subject | Mercury | pt_BR |
dc.subject | Atomic fluorescence spectrometry | pt_BR |
dc.subject | Multisyringe | pt_BR |
dc.subject | Rice | pt_BR |
dc.title | Determination of mercury in rice by MSFIA and cold vapour atomic fluorescence spectrometry | pt_BR |
dc.title.alternative | Food Chemistry | pt_BR |
dc.type | Artigo de Periódico | pt_BR |
dc.description.localpub | Salvador | pt_BR |
dc.identifier.number | v. 137, n. 1–4 | pt_BR |
Aparece nas coleções: | Artigo Publicado em Periódico (Química)
|