Skip navigation
Universidade Federal da Bahia |
Repositório Institucional da UFBA
Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/12100
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorRebouças, Márcio das Virgens-
dc.contributor.authorDomingos, Daniela-
dc.contributor.authorSantos, Aline S. O.-
dc.contributor.authorSampaio, Leilacy-
dc.creatorRebouças, Márcio das Virgens-
dc.creatorDomingos, Daniela-
dc.creatorSantos, Aline S. O.-
dc.creatorSampaio, Leilacy-
dc.date.accessioned2013-07-04T15:27:56Z-
dc.date.issued2010-11-
dc.identifier.issn0378-3820-
dc.identifier.urihttp://www.repositorio.ufba.br/ri/handle/ri/12100-
dc.descriptionTexto completo: acesso restrito. p.1702-1709pt_BR
dc.description.abstractNaphtha is a volatile petroleum fraction containing C4–C15 hydrocarbon compounds used as feedstock for petrochemical processes which are seriously affected by trace metals. Simple methods for copper, iron, lead and silicon determination in naphtha using graphite furnace atomic absorption spectrometry (GFAAS) have been developed. Two different approaches are presented: direct injection of the sample and oil-in-water microemulsion formation using a mixture of the sample, propan-1-ol and nitric acid aqueous solution. The calibration curves showed linear response for each concentration range with correlation coefficients ranging from 0.9728 to 0.9998. Precision figures of 1.7–20%, reported as the relative standard deviation, were calculated from at least twenty consecutive measurements of solutions containing the metal in a concentration level below 100 μg L−1. The characteristic masses varied from 8.5 to 44 pg and the limit of detection, defined as the metal concentration that gives a response equivalent to three times the standard deviation of the blank (n = 10), was found to be within the range 0.01–26 μg L−1. A critical analysis is presented by the authors emphasizing the advantages and limitations of both approaches. The proposed procedures have been used for copper, iron, lead and silicon determination in naphtha feeds processed in Braskem S.A. (Camacari, Bahia, Brazil).pt_BR
dc.language.isoenpt_BR
dc.sourcehttp://dx.doi.org/10.1016/j.fuproc.2010.07.007pt_BR
dc.subjectMetalspt_BR
dc.subjectNaphthapt_BR
dc.subjectPetroleum productspt_BR
dc.subjectMicroemulsionpt_BR
dc.subjectGFAASpt_BR
dc.subjectETAASpt_BR
dc.titleDetermination of trace metals in naphtha by graphite furnace atomic absorption spectrometry: Comparison between direct injection and microemulsion pretreatment procedurespt_BR
dc.title.alternativeFuel Processing Technologypt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 91, n. 11pt_BR
dc.embargo.liftdate10000-01-01-
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
1-s2.0-S0378382010002390-main.pdf
  Restricted Access
285,42 kBAdobe PDFVisualizar/Abrir Solicitar uma cópia
Mostrar registro simples do item Visualizar estatísticas


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.