Campo DC | Valor | Idioma |
dc.contributor.author | Lemos, Valfredo Azevedo | - |
dc.contributor.author | Santelli, Ricardo Erthal | - |
dc.contributor.author | Carvalho, Marcelo Souza de | - |
dc.contributor.author | Ferreira, Sergio Luis Costa | - |
dc.creator | Lemos, Valfredo Azevedo | - |
dc.creator | Santelli, Ricardo Erthal | - |
dc.creator | Carvalho, Marcelo Souza de | - |
dc.creator | Ferreira, Sergio Luis Costa | - |
dc.date.accessioned | 2013-07-24T17:11:33Z | - |
dc.date.available | 2013-07-24T17:11:33Z | - |
dc.date.issued | 2000 | - |
dc.identifier.issn | 0584-8547 | - |
dc.identifier.uri | http://www.repositorio.ufba.br/ri/handle/ri/12282 | - |
dc.description | Texto completo. Acesso restrito. p. 1497–1502 | pt_BR |
dc.description.abstract | In the present paper, the use of polyurethane foam modified by 2-(2-benzothiazolylazo)-2-p-cresol (BTAC) as a sorbent in an on-line preconcentration system to determine cadmium trace levels by FAAS is proposed. The procedure was based on the chemical sorption of cadmium (II) ions onto a minicolumn packed with polyurethane foam, followed by 0.10 mol l−1 hydrochloric acid elution and direct determination by Flame Atomic Absorption Spectrometry. The flow system was operated in a time-based mode. Chemical and flow variables were studied. Results demonstrated that sample solutions containing cadmium(II) in the range of concentration from 0.91 to 30.00 μg l−1, pH between 6.50 and 9.25 could be determinated by this procedure, in a preconcentration time of 1 min. Flow rates in preconcentration and elution steps were 7.00 and 4.00 ml min−1, respectively. The precision of the preconcentration procedure (evaluated as standard deviation of solutions containing 1.0–30.0 μg l−1 of cadmium) varied in the range from 5 to 1%. The preconcentration factor, calculated as the ratio of the linear section of the slopes of the analytical curves before and after preconcentration, was 41, for a volume sample of 7.00 ml. The detection limit was 0.27 μg l−1 for a preconcentration time of 1 min. The proposed procedure was applied for determination of cadmium in biological reference materials. Achieved results demonstrated that the procedure can be applied for analysis of biological materials with satisfactory accuracy. | pt_BR |
dc.language.iso | en | pt_BR |
dc.publisher | Spectrochimica Acta Part B: Atomic Spectroscopy | pt_BR |
dc.source | http://dx.doi.org.ez10.periodicos.capes.gov.br/10.1016/S0584-8547(00)00257-3 | pt_BR |
dc.subject | Cadmium | pt_BR |
dc.subject | On-line preconcentration | pt_BR |
dc.subject | Polyurethane foam | pt_BR |
dc.subject | Flame AAS | pt_BR |
dc.title | Application of polyurethane foam loaded with BTAC in an on-line preconcentration system: cadmium determination by FAAS | pt_BR |
dc.title.alternative | Spectrochimica Acta Part B: Atomic Spectroscopy | pt_BR |
dc.type | Artigo de Periódico | pt_BR |
dc.description.localpub | Salvador | pt_BR |
dc.identifier.number | v. 55, n. 9 | pt_BR |
Aparece nas coleções: | Artigo Publicado em Periódico (Química)
|