Skip navigation
Universidade Federal da Bahia |
Repositório Institucional da UFBA
Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/15642
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorPinheiro, Antonio Luiz Barbosa-
dc.contributor.authorSoares, Luiz Guilherme Pinheiro-
dc.contributor.authorBarbosa, Artur Felipe Santos-
dc.contributor.authorRamalho, Luciana Maria Pedreira-
dc.contributor.authorSantos, Jean Nunes dos-
dc.creatorPinheiro, Antonio Luiz Barbosa-
dc.creatorSoares, Luiz Guilherme Pinheiro-
dc.creatorBarbosa, Artur Felipe Santos-
dc.creatorRamalho, Luciana Maria Pedreira-
dc.creatorSantos, Jean Nunes dos-
dc.date.accessioned2014-08-18T16:44:15Z-
dc.date.issued2012-
dc.identifier.issn0268-8921-
dc.identifier.urihttp://repositorio.ufba.br/ri/handle/ri/15642-
dc.descriptionTexto completo: acesso restrito. p.1013–1024pt_BR
dc.description.abstractThis work carried out a histological analysis on bone defects grafted (MTA) treated or not with LED, BMPs, and membrane (GBR). Benefits of their isolated or combined usage on bone repair were reported, but not their association. Ninety rats were divided into ten groups and each subdivided into three. Defects on G II and I were filled with the blood clot. G II was further LED irradiated. G III and IV were filled with MTA; G IV was further LED irradiated. In G V and VI, the defects were filled with MTA and covered with a membrane (GBR). G VI was further LED irradiated. In G VII and VIII, BMPs were added to the MTA and group VIII was further LED irradiated. In G IX and X, the MTA + BMP graft was covered with a membrane (GBR). G X was further LED irradiated. LED was applied over the defect at 48-h intervals and repeated for 15 days. Specimens were processed, cut, and stained with H&E and Sirius red and underwent histological analysis. The use of LED light alone dramatically reduced inflammation. However, its use on MTA associated with BMP and/or GBR increased the severity of the inflammatory reaction. Regarding bone reabsorption, the poorest result was seen when the LED light was associated with the MTA + BMP graft. In the groups Clot and MTA + GBR, no bone reabsorption was detectable. Increased collagen deposition was observed when the LED light was associated with the use of the MTA associated with BMP and/or GBR. Increased new bone formation was observed when the LED light was used alone or associated with the use of MTA + GBR, MTA + BMP, on association of MTA + BMP + GBR and when BMP was added to the MTA. Our results indicate that the use of LED light alone or in association with MTA, MTA + BMP, MTA + GBR, and MTA + BMP + GBR caused less inflammation, and an increase of both collagen deposition and bone deposition as seen on both histological and morphometric analysis.pt_BR
dc.language.isoenpt_BR
dc.rightsAcesso Abertopt_BR
dc.sourcehttp://dx.doi.org/ 10.1007/s10103-011-1033-8pt_BR
dc.subjectBiomaterialpt_BR
dc.subjectLight emitting diodept_BR
dc.subjectMineral trioxide aggregatept_BR
dc.titleDoes LED phototherapy influence the repair of bone defects grafted with MTA, bone morphogenetic proteins, and guided bone regeneration? A description of the repair process on rodentspt_BR
dc.title.alternativeLasers in Medical Sciencept_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 27, n. 5pt_BR
dc.embargo.liftdate10000-01-01-
Aparece nas coleções:Artigo Publicado em Periódico (Faculdade de Odontologia)

Arquivos associados a este item:
Não existem arquivos associados a este item.
Mostrar registro simples do item Visualizar estatísticas


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.