Skip navigation
Universidade Federal da Bahia |
Repositório Institucional da UFBA
Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/15644
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorVaz, Sergio Lins de Azevedo-
dc.contributor.authorAlencar, Phillipe Nogueira Barbosa-
dc.contributor.authorRovaris, Karla-
dc.contributor.authorCampo, Paulo Sérgio Flores-
dc.contributor.authorHaiter Neto, Francisco-
dc.creatorVaz, Sergio Lins de Azevedo-
dc.creatorAlencar, Phillipe Nogueira Barbosa-
dc.creatorRovaris, Karla-
dc.creatorCampo, Paulo Sérgio Flores-
dc.creatorHaiter Neto, Francisco-
dc.date.accessioned2014-08-18T17:06:55Z-
dc.date.issued2013-
dc.identifier.issn2212-4403-
dc.identifier.urihttp://repositorio.ufba.br/ri/handle/ri/15644-
dc.descriptionTexto completo: acesso restrito. p. 633–639pt_BR
dc.description.abstractObjective: To investigate whether cone beam computed tomography filters would improve periimplant dehiscence detection. Study design: A hundred titanium implants were placed in bovine ribs in which defects simulating periimplant dehiscence had previously been created. After images acquisition, three oral radiologists assessed them with and without the following filters: Angio Sharpen high 5 × 5, Shadow, Sharpen 3 × 3, Sharpen Mild, and Smooth. The McNemar test verified the disagreement between all images versus the reference standard and original images versus images with filters; P < .05 was considered statistically significant. Results: Dehiscence detection using the original images and the Shadow filter disagreed from the reference standard (P < .05), as well as when using the filters instead of the original images (P < .05). Conclusion: All the filters tested, with the exception of the Shadow, improved periimplant dehiscence detection. The Sharpen 3 × 3 filter was considered best for this task.pt_BR
dc.language.isoenpt_BR
dc.rightsAcesso Abertopt_BR
dc.sourcehttp://dx.doi.org/10.1016/j.oooo.2013.06.029pt_BR
dc.subjectTomography, X-Ray Computedpt_BR
dc.subjectProstheses and Implantspt_BR
dc.titleEnhancement cone beam computed tomography filters improve in vitro periimplant dehiscence detectionpt_BR
dc.title.alternativeOral Surgery, Oral Medicine, Oral Pathology and Oral Radiologypt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 116, n. 5pt_BR
dc.embargo.liftdate10000-01-01-
Aparece nas coleções:Artigo Publicado em Periódico (Faculdade de Odontologia)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
1-s2.0-S2212440313003507-main.pdf477,1 kBAdobe PDFVisualizar/Abrir
Mostrar registro simples do item Visualizar estatísticas


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.