Skip navigation
Universidade Federal da Bahia |
Repositório Institucional da UFBA
Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/15647
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorBrandão, Geovani Cardoso-
dc.contributor.authorAureliano, Márcio de Oliveira-
dc.contributor.authorSauthier, Maria Celeste da Silva-
dc.contributor.authorSantos, Walter Nei Lopes dos-
dc.creatorBrandão, Geovani Cardoso-
dc.creatorAureliano, Márcio de Oliveira-
dc.creatorSauthier, Maria Celeste da Silva-
dc.creatorSantos, Walter Nei Lopes dos-
dc.date.accessioned2014-08-19T14:26:21Z-
dc.date.available2014-08-19T14:26:21Z-
dc.date.issued2012-
dc.identifier.issn1759-9660-
dc.identifier.urihttp://repositorio.ufba.br/ri/handle/ri/15647-
dc.descriptionp. 855–858pt_BR
dc.description.abstractThe present work proposes the photo-oxidation using UV radiation/H2O2 as an alternative procedure for pretreatment of industrialized fruit juice samples for determination of copper by flame atomic absorption spectrometry (FAAS). For optimization of the photo-oxidation procedure the following variables were studied: pH and volume of buffer solution, volume of concentrated hydrogen peroxide and irradiation time. The sample degradation was monitored by molecular absorption spectrometry in the spectral range of 200–800 nm. The established conditions were: pH 10, volume of buffer of 1.0 mL, volume of concentrated hydrogen peroxide of 1.5 mL and irradiation time of 90 min, for a 5 mL volume of the photo-digested sample. An external calibration technique with aqueous standard was used for copper quantification. Under these conditions, the method allows the copper determination with limits of detection and quantification of 7 and 22 μg L−1, respectively. The precision, expressed as relative standard deviation (RSD), was 1.43 and 0.27% for copper concentrations of 0.2 and 2.0 μg mL−1, respectively. The accuracy of the method was evaluated for five industrialized fruit juice samples (orange, grape, mango, passion fruit and peach) and the results compared with those obtained after acid digestion of the samples and determination by FAAS. No significant difference was observed between the results obtained by both procedures, applying a paired t-test at the 95% confidence level.pt_BR
dc.language.isoenpt_BR
dc.rightsAcesso Abertopt_BR
dc.sourcehttp://dx.doi.org/ 10.1039/C2AY05438Hpt_BR
dc.titlePhoto-oxidation using UV radiation as a sample preparation procedure for the determination of copper in fruit juices by flame atomic absorption spectrometrypt_BR
dc.title.alternativeAnalytical Methodspt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 4, n. 3pt_BR
dc.publisher.countryBrasilpt_BR
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Não existem arquivos associados a este item.
Mostrar registro simples do item Visualizar estatísticas


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.