Skip navigation
Universidade Federal da Bahia |
Repositório Institucional da UFBA
Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/15706
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorCastilho, Ivan N. B.-
dc.contributor.authorWelz, Bernhard-
dc.contributor.authorAndrade, Jailson Bittencourt de-
dc.contributor.authorSmichowski, Patricia-
dc.contributor.authorShaltout, Abdallah A.-
dc.contributor.authorColares, Lígia-
dc.contributor.authorCarasek, Eduardo-
dc.creatorCastilho, Ivan N. B.-
dc.creatorWelz, Bernhard-
dc.creatorAndrade, Jailson Bittencourt de-
dc.creatorSmichowski, Patricia-
dc.creatorShaltout, Abdallah A.-
dc.creatorColares, Lígia-
dc.creatorCarasek, Eduardo-
dc.date.accessioned2014-08-26T13:18:20Z-
dc.date.issued2012-
dc.identifier.issn0039-9140-
dc.identifier.urihttp://repositorio.ufba.br/ri/handle/ri/15706-
dc.descriptionTexto completo: acesso restrito. p. 689–695pt_BR
dc.description.abstractThree different procedures for sample preparation have been compared for the determination of Cu, Mo and Sb in airborne particulate matter (APM) collected on glass fiber filters using high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GF AAS). Direct solid sample analysis of the ground filters was compared with microwave-assisted acid leaching with aqua regia and ultrasound-assisted extraction also using aqua regia. The main absorption line at 324.754 nm or the secondary line at 216.509 nm was used for the determination of Cu, depending on the analyte content in the samples. The primary absorption line at 313.259 nm was used for Mo and the secondary line at 212.739 nm for Sb determination. The limits of detection (LOD, 3σ) found for the direct solid sampling method, based on ten atomizations of an unused filter were 15 μg g−1 for all three analytes, corresponding to 40 ng m−3 for a typical air volume of 1440 m3 collected over a period of 24 h. The LOD for the other two methods were less than a factor of two inferior, but the total time required for an analysis was significantly longer. The repeatability of the measurements was between 3 and 9% (n = 5), and the results obtained with the three methods did not show any significant difference. The ratio between the three analytes on the filters from areas of intense traffic was found to be around Cu:Mo:Sb ≈ 4:1:1.4, which suggests that the source of all three elements is brake linings, i.e., related to automobile traffic. When the ratio deviated significantly from the above values, the source of contamination was assumed to be of different origin.pt_BR
dc.language.isoenpt_BR
dc.rightsAcesso Abertopt_BR
dc.sourcehttp://dx.doi.org/ 10.1016/j.talanta.2011.11.066pt_BR
dc.subjectHigh-resolution continuum source AASpt_BR
dc.subjectTraffic-related elementspt_BR
dc.subjectGlass fiber filterspt_BR
dc.subjectDirect solid samplingpt_BR
dc.titleComparison of three different sample preparation procedures for the determination of traffic-related elements in airborne particulate matter collected on glass fiber filterspt_BR
dc.title.alternativeTalantapt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 88 n. 15pt_BR
dc.embargo.liftdate10000-01-01-
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Ivan N. B. Castilho.pdf625,94 kBAdobe PDFVisualizar/Abrir
Mostrar registro simples do item Visualizar estatísticas


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.