Skip navigation
Universidade Federal da Bahia |
Repositório Institucional da UFBA
Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/35312
Registro completo de metadados
Campo DCValorIdioma
dc.creatorCarvalho, Guilherme Nunes de-
dc.date.accessioned2022-05-23T13:48:56Z-
dc.date.available2022-05-04-
dc.date.available2022-05-23T13:48:56Z-
dc.date.issued2021-12-15-
dc.identifier.urihttps://repositorio.ufba.br/handle/ri/35312-
dc.description.abstractThe process of dental plaque detection and quantification is important to guide the patient and dentist in the diagnosis and dental treatment plan, plaque control, as well as for epidemiological studies. The aim of this study was to evaluate the accuracy of the detection and quantification of dental plaque in permanent teeth by human vision, analyzing intraoral photographs. A diagnostic study was conducted, with a sample composed of images of 30 volunteers selected among the patients from a dental clinic in the city of Salvador. Intraoral photographs before and after dental plaque evidencing through dyes agents (gold standard) were analyzed for the presence and quantity of dental plaque. Two dentist examiners evaluated the photographs without disclosing, and one of them also evaluated the disclosing photographs. Examiner 1 analyzed 638 dental surfaces and examiner 2, 336 dental surfaces. The ROC curve, F1 score and the intra- and inter-examiner agreement of five dental plaque indices were calculated. The highest intra-examiner agreement was found for the dental plaque percentage, with an ICC of 0.934 and the lowest was for the navy plaque index with a weighted kappa of 0.602. The highest inter-examiner agreement found was for the percentage of dental plaque with an ICC of 0.883 and the lowest was for dental plaque detection with a kappa of 0.058. The area under the ROC curve and F1 score found for the dental plaque detection of the first examiner were 0.751 and 0.880, respectively, and for the second examiner they were 0.568 and 0.893, respectively. The area under the ROC curve and F1 score found for the dental plaque quantification of the first examiner were 0.763 and 0.709, respectively, and for the second examiner they were 0.828 and 0.800, respectively. Thus, it is possible to conclude that visual detection and, mainly, the quantification of dental plaque in photographs of permanent teeth without disclosing is a sufficiently accurate method, which may mean more savings, simplicity and less time in dental treatments.pt_BR
dc.languageporpt_BR
dc.publisherUniversidade Federal da Bahiapt_BR
dc.rightsAcesso Abertopt_BR
dc.subjectPlaca Dentáriapt_BR
dc.subjectFotografia Dentáriapt_BR
dc.subjectÍndice de Placa Dentáriapt_BR
dc.subject.otherDental Plaquept_BR
dc.subject.otherPhotography Dentalpt_BR
dc.subject.otherDental Plaque Indexpt_BR
dc.titleAcurácia da detecção e quantificação de placa dentária em fotografias intrabucaispt_BR
dc.title.alternativeAccuracy of detection and quantification of dental plaque in intraoral photographspt_BR
dc.typeDissertaçãopt_BR
dc.publisher.programPrograma de Pós-Graduação em Odontologia e Saúde pt_BR
dc.publisher.initialsUFBApt_BR
dc.publisher.countryBrasilpt_BR
dc.subject.cnpqCNPQ::CIENCIAS DA SAUDE::ODONTOLOGIApt_BR
dc.contributor.advisor1Cury, Patrícia Ramos-
dc.contributor.advisor1IDhttps://orcid.org/0000-0001-8907-0483pt_BR
dc.contributor.advisor1Latteshttp://lattes.cnpq.br/0714090324773908pt_BR
dc.contributor.referee1Cury, Patricia Ramos-
dc.contributor.referee1IDhttps://orcid.org/0000-0001-8907-0483pt_BR
dc.contributor.referee1Latteshttp://lattes.cnpq.br/0714090324773908pt_BR
dc.contributor.referee2Santos, Jean Nunes dos-
dc.contributor.referee2IDhttp://lattes.cnpq.br/0926138204356872pt_BR
dc.contributor.referee2Latteshttp://lattes.cnpq.br/0926138204356872pt_BR
dc.contributor.referee3Araujo, Nara Santos-
dc.contributor.referee3IDhttps://orcid.org/0000-0002-1166-8300pt_BR
dc.creator.IDhttps://orcid.org/0000-0002-3595-2496pt_BR
dc.creator.Latteshttp://lattes.cnpq.br/4942856345349374pt_BR
dc.description.resumoO processo de detecção e quantificação de placa bacteriana dentária é importante para guiar paciente e dentista em relação ao diagnóstico e plano de tratamento odontológicos, controle da placa, bem como para realização de estudos epidemiológicos. O objetivo desse estudo foi avaliar a acurácia da detecção e quantificação de placa dentária em dentes permanentes pela visão humana, analisando fotografias intrabucais. Foi realizado um estudo transversal diagnóstico, com amostra composta por imagens de 30 voluntários selecionados entre os pacientes de uma clínica odontológica da cidade de Salvador. Fotografias intrabucais antes e depois de evidenciação de placa dentária através de agentes corantes (padrão-ouro) foram analisadas quanto a presença e quantidade de placa dentária. Dois examinadores cirurgiões-dentistas avaliaram as fotografias não evidenciadas, e um deles também avaliou as fotografias evidenciadas. O examinador 1 analisou 638 superfícies dentárias e o examinador 2, 336 superfícies dentárias. Foram calculadas a curva ROC, score F1 e a concordância intra e interexaminadores de cinco índices de placa. A maior concordância intraexaminador encontrada foi para a porcentagem de placa, com um ICC de 0,934 e a menor foi para o navy plaque index com um kappa ponderado de 0,602. A maior concordância interexaminadores encontrada foi para a porcentagem de placa com um ICC de 0,883 e a menor foi para a detecção de placa com um kappa de 0,058. A área abaixo da curva ROC e score F1 encontrados para a detecção de placa do primeiro examinador foram de 0,751 e 0,880 respectivamente, e para o segundo examinador foram de 0,568 e 0,893 respectivamente. A área abaixo da curva ROC e score F1 encontrados para a quantificação de placa do primeiro examinador foram de 0,763 e 0,709 respectivamente, e para o segundo examinador foram de 0,828 e 0,800 respectivamente. Dessa forma, é possível concluir que a detecção visual e, principalmente a quantificação de placa dentária em fotografias de dentes permanentes sem evidenciação é um método suficientemente acurado, podendo significar mais economia, simplicidade e menos tempo nos tratamentos odontológicos.pt_BR
dc.publisher.departmentFaculdade de Odontologiapt_BR
Aparece nas coleções:Dissertação (POSDONTO)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
dissertação final 2022.pdf1,27 MBAdobe PDFVisualizar/Abrir
Mostrar registro simples do item Visualizar estatísticas


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.