Skip navigation
Universidade Federal da Bahia |
Repositório Institucional da UFBA
Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/36663
Tipo: Dissertação
Título: AVALIAÇÃO DA UTILIZAÇÃO DE TRÊS DIFERENTES INSTRUMENTOS EM CANAIS ARTIFICIAIS CALCIFICADOS NA ENDODONTIA GUIADA
Autor(es): Brito, Marcella Andrade
Primeiro Orientador: Araujo, Danilo Barral de
Segundo Orientador: da Matta, Mônica Cardoso
metadata.dc.contributor.advisor-co1: Araujo, Danilo Barral de
metadata.dc.contributor.advisor-co2: da Matta, Mônica Cardoso
metadata.dc.contributor.referee1: Araujo, Danilo Barral de
metadata.dc.contributor.referee2: Rasquin, Luis Cardoso
metadata.dc.contributor.referee3: da Matta, Mônica Cardoso
Resumo: Introdução – A calcificação pulpar implica um elevado grau de dificuldade durante o acesso endodôntico. Na tentativa de localizar o canal, pode haver desvio do trajeto original e perfurações. Para minimiziar esses riscos, a endodontia guiada surgiu como uma abordagem mais precisa e segura. Metodologia – Sessenta e seis incisivos centrais inferiores artificiais foram divididos em três grupos, de acordo com o instrumento utilizado para realizar o acesso guiado: fresa ø1.3mm de implantodontia, fresa ø1.0 mm Kit Radiodôntica e fresa ø1.0 mm Kit Endo Guide. Foram ainda distribuídos em dois grupos, segundo a presença ou não da anilha no guia endodôntico (N=11). Os guias utilizados foram impressos através da associação da TCFC com o escaneamento digital. Para a avaliação do desvio, foi feita a sobreposição das imagens do planejamento digital com a TCFC pós-acesso no software NemoTec. Resultados – A fresa de implantodontia apresentou a menor média de desvio com (0,2682 ± 0,12890) no acesso guiado com anilha e (0,4109 ± 0,33399) no acesso sem anilha. Quando esse instrumento foi comparado com os demais, houve uma variação do desvio significante apenas em relação à fresa ø1.0 mm Radiodôntica, com p=0,000 nos guias com anilha e p=0,003 nos guias sem anilha. Quando a influência da anilha no guia foi relacionada com o desvio, apenas a fresa Radiodôntica apresentou diferença significativa com p=0,020. Conclusão – A fresa ø1.0 mm Kit Radiodôntica foi o único instrumento que apresentou diferença significativa na comparação de desvio entre os instrumentos e na avaliação da influência da anilha sobre o desvio.
Abstract: Introduction - Pulp calcification implies a high degree of difficulty during endodontic access. In an attempt to locate the channel, there may be deviation from the original route and perforations. To minimize these risks, guided endodontics emerged as a more accurate and safe approach. Methodology - Sixty-six artificial lower central incisors were divided into three groups, according to the instrument used to perform guided access: milling Ø1.3mm of implantology, milling Ø1.0 mm Radiodontic Kit, Ø1.0 mm Kit Endo Guide. They were also distributed in two groups, according to the presence or not of the endodontic guide (n = 11). The guides used were printed through the TCFC association with digital scanning. For the evaluation of the deviation, the digital planning images were overlap with the post-access TCFC in the NemoTec. software. Results - The implantology cutter presented the lowest average deviation with (0.2682 ± 0.12890) in guided access with the washer and (0.4109 ± 0.33399) on non-treat access. When this instrument was compared to the others, there was a variation of the significant deviation only in relation to the Radiodontic cutter, with p = 0.000 in the washer guides and p = 0.003 in the non -treat guides. When the influence of the washer in the guide was related to the deviation, only the Radiodontic washer showed significant difference with p = 0.020. Conclusion - The Ø1.0 mm Radiodontic Kit cutter was the only instrument that presented a significant difference in the comparison of deviation, among the instruments and the assessment of the washer influence on the deviation.
Palavras-chave: Calcificações da Polpa Dentária
Endodontia
Tomografia Computadorizada de Feixe Cônico
Procedimentos cirúrgicos não invasivos
CNPq: CNPQ::CIENCIAS DA SAUDE
Idioma: por
País: Brasil
Editora / Evento / Instituição: Universidade Federal da Bahia
Sigla da Instituição: UFBA
metadata.dc.publisher.department: Instituto de Ciências da Saúde - ICS
metadata.dc.publisher.program: Programa de Pós-Graduação em Processos Interativos dos Órgãos e Sistemas (PPGORGSISTEM) 
Tipo de Acesso: Attribution-NonCommercial-NoDerivs 3.0 Brazil
metadata.dc.rights.uri: http://creativecommons.org/licenses/by-nc-nd/3.0/br/
URI: https://repositorio.ufba.br/handle/ri/36663
Data do documento: 21-Dez-2022
Aparece nas coleções:Dissertação (PPGPIOS)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
DISSERTAÇÃO - Marcella Andrade Brito.pdf1,72 MBAdobe PDFVisualizar/Abrir
Mostrar registro completo do item Visualizar estatísticas


Este item está licenciada sob uma Licença Creative Commons Creative Commons