https://repositorio.ufba.br/handle/ri/40310
Tipo: | Dissertação |
Título: | Avaliação da associação entre a fração de óxido nítrico exalada (FeNO), controle da asma e técnica de uso dos dispositivos inalatórios em indivíduos com asma |
Título(s) alternativo(s): | Evaluation of the association between the fraction of exhaled nitric oxide (FeNO), asthma control and technique of use of inhalation devices in individuals with asthma |
Autor(es): | Inácio, Débora dos Santos |
Primeiro Orientador: | Cruz Filho, Álvaro Augusto Souza da |
metadata.dc.contributor.referee1: | Cruz Filho, Álvaro Augusto Souza da |
metadata.dc.contributor.referee2: | Fernandes, Andréa Guedes Oliva |
metadata.dc.contributor.referee3: | Coelho, Ana Carla Carvalho |
Resumo: | Introdução: A asma é uma doença inflamatória crônica das vias aéreas de elevada morbimortalidade, sendo um importante problema de saúde pública. A administração da medicação com uma adequada manobra respiratória e um marcador de inflamação podem ser ferramentas importantes no controle da asma. Objetivo: Verificar se existe associação entre os níveis de óxido nítrico exalado e a técnica de uso dos dispositivos inalatórios com o controle da asma em indivíduos com asma e avaliar técnica do uso de dispositivos inalatórios em comparação aos valores de óxido nítrico e controle da asma. Metodologia: estudo de corte transversal com indivíduos com asma atendidos em um centro especializado em Salvador - BA. Foi realizada coleta de dados sociodemográficos, avaliação da inflamação das vias aéreas através do FeNO, teste de função pulmonar e questionários para avaliação do controle da asma, adesão ao tratamento e avaliação da técnica para uso do dispositivo inalatório. Foram realizadas medidas de tendência central e dispersão para variáveis contínuas e frequências relativas e absolutas para variáveis categóricas. Realizados os testes estatísticos Teste t de Student, Correlação de Pearson e Testes Qui-Quadrado. Resultados: Valores de FeNO entre 25 e 40 ppb (OR = 2,12; IC 95% = 1,19-3,78; p = 0,012) e acima de 40 ppb (OR = 3,49; IC 95% = 1,97-6,19; p < 0,001) estão associados a maiores chances de asma parcialmente ou não controlada e técnica inadequada (OR = 1,92; IC 95% = 1,10-3,35; p = 0,020) e erros críticos na técnica inalatória (OR = 3,00; IC 95% = 1,55-5,80; p = 0,001) também foram associados a maiores chances de asma não controlada. Conclusão: os valores de FeNO acima de 25 ppb e a realização da técnica inalatória de forma inadequadas ou com erros críticos no uso de dispositivos inalatórios estão associados a um pior controle da asma e esta compreensão pode contribuir para a melhoria das estratégias de manejo da asma. |
Abstract: | Introduction: Asthma is a chronic inflammatory disease of the airways with high morbidity and mortality, being an important public health problem. Medication administration with an adequate respiratory maneuver and an inflammation marker can be important tools in controlling asthma. Aim: to verify whether there is an association between exhaled nitric oxide levels and the technique of using inhaler devices with asthma control in individuals with asthma and to evaluate the technique of using inhaler devices in comparison to nitric oxide values and asthma control.. Methodology: crosssectional study with individuals with asthma treated at a specialized center in Salvador - BA. Sociodemographic data was collected, airway inflammation was assessed using FeNO, pulmonary function testing and questionnaires were carried out to assess asthma control, adherence to treatment and assessment of the technique for using the inhalation device. Measures of central tendency and dispersion were performed for continuous variables and relative and absolute frequencies for categorical variables. Statistical tests were carried out Student's t-test, Pearson Correlation and Chi-Square Tests. Results: FeNO values between 25 and 40 ppb (OR = 2.12; 95% CI = 1.19-3.78; p = 0.012) and above 40 ppb (OR = 3.49; 95% CI = 1 .97-6.19; p < 0.001) are associated with greater odds of partially or uncontrolled asthma and inadequate technique (OR = 1.92; 95% CI = 1.10-3.35; p = 0.020) and errors critical inhalation technique (OR = 3.00; 95% CI = 1.55-5.80; p = 0.001) were also associated with greater odds of uncontrolled asthma. Conclusion: FeNO values above 25 ppb and inadequate inhalation technique or critical errors in the use of inhalation devices are associated with worse asthma control and this understanding can contribute to improving asthma management strategies. |
Palavras-chave: | Asma Óxido Nítrico Dispositivo inalatório Controle |
CNPq: | CNPQ::CIENCIAS DA SAUDE |
Idioma: | por |
País: | Brasil |
Editora / Evento / Instituição: | PROGRAMA DE PÓS GRADUAÇÃO CIÊNCIAS DA SAÚDE |
Sigla da Instituição: | ICS-UFBA |
metadata.dc.publisher.department: | Instituto de Ciências da Saúde - ICS |
metadata.dc.publisher.program: | Pós-Graduação em Ciências da Saúde (POS_CIENCIAS_SAUDE) |
Citação: | INÁCIO, Débora dos Santos. Avaliação da associação entre a fração de óxido exalado (feNO), controle da asma e técnica de uso dos dispositivos inalatórios em indivíduos com asma. 2024. 69 f. Dissertação (Mestrado em Ciências da Saúde) - Faculdade de Medicina da Bahia, Universidade Federal da Bahia, Salvador, 2024. |
Tipo de Acesso: | Acesso Restrito/Embargado |
URI: | https://repositorio.ufba.br/handle/ri/40310 |
Data do documento: | 26-Jul-2024 |
Aparece nas coleções: | Dissertação (PPgCS) |
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
DISSERTAÇÃO DÉBORAINÁCIO.pdf Until 2025-09-30 | 5,27 MB | Adobe PDF | Visualizar/Abrir Solicitar uma cópia |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.