Título: | Direct determination of arsenic in petroleum derivatives by graphite furnace atomic absorption spectrometry: A comparison between filter and platform atomizers |
Título(s) alternativo(s): | Spectrochimica acta part b-antomic spectroscopy |
Autor(es): | Becker, Emilene M. Rampazzo, Roger T. Dessuy, Morgana B. Vale, Maria Goreti R. Silva, Márcia M. da Welz, Bernhard Katskov, Dmitri A. |
Autor(es): | Becker, Emilene M. Rampazzo, Roger T. Dessuy, Morgana B. Vale, Maria Goreti R. Silva, Márcia M. da Welz, Bernhard Katskov, Dmitri A. |
Abstract: | In the present work a direct method for the determination of arsenic in petroleum derivatives has been developed, comparing the performance of a commercial transversely heated platform atomizer (THPA) with that of a transversely heated filter atomizer (THFA). The THFA results in a reduction of background absorption and an improved sensitivity as has been reported earlier for this atomizer. The mixture of 0.1% (m/v) Pd+0.03% (m/v) Mg+0.05% (v/v) Triton X-100 was used as the chemical modifier for both atomizers. The samples (naphtha, gasoline and petroleum condensate) were stabilized in the form of a three-component solution (detergentless microemulsion) with the sample, propan-1-ol and 0.1% (v/v) HNO3 in a ratio of 3.0:6.4:0.6. The characteristic mass of 13 pg found in the THFAwas about a factor of two better than that of 28 pg obtained with the THPA; however, the limits of detection (LOD) and quantification (LOQ) were essentially the samefor both atomizers (1.9 and 6.2 μg L−1, respectively, for THPA, and 1.8 and 5.9 μg L−1, respectively, for THFA) due to the increased noise observed with the THFA. A possible explanation for that is a partial blockage of the radiation from the hollow cathode lamp by the narrow inner diameter of this tube and the associated loss of radiation energy. Due to the lack of an appropriate certified reference material, recovery tests were carried out with inorganic and organic arsenic standards and the resultswere between 89% and 111%. The only advantage of the THFA found in this work was a reduction of the total analysis time by about 20% due to the ‘hot injection’ that could be realized with this furnace. The arsenic concentrations varied from bLOQ to 43.3 μg L−1 in the samples analyzed in this work. |
Palavras-chave: | Transversely heated filter atomizer Petroleum derivative Three-component solution Detergentless microemulsion Arsenic determination |
URI: | http://www.repositorio.ufba.br/ri/handle/ri/5393 |
Data do documento: | 2011 |
Aparece nas coleções: | Artigo Publicado em Periódico (Química) |
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
C__Documents and Settings_rep...t.default_Cache_E_FA_5415Cd01.pdf Restricted Access | 226,98 kB | Adobe PDF | Visualizar/Abrir Solicitar uma cópia |
Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.