Campo DCValorIdioma
dc.contributor.authorAraujo, André R. T. S.-
dc.contributor.authorSaraiva, Maria Lúcia M. F. S.-
dc.contributor.authorLima, José Luis Fontes da Costa-
dc.contributor.authorKorn, Maria das Graças Andrade-
dc.creatorAraujo, André R. T. S.-
dc.creatorSaraiva, Maria Lúcia M. F. S.-
dc.creatorLima, José Luis Fontes da Costa-
dc.creatorKorn, Maria das Graças Andrade-
dc.date.accessioned2012-06-28T19:45:17Z-
dc.date.issued2008-
dc.identifier.issn0003-2670-
dc.identifier.urihttp://www.repositorio.ufba.br/ri/handle/ri/6256-
dc.descriptionAcesso restrito: Texto completo. p. 177-183pt_BR
dc.description.abstractA methodology based in flow analysis and membrane-based extraction has been applied to the determination of methanol in biodiesel samples. A hydrophilic membrane was used to perform the liquid–liquid extraction in the system with the organic sample fed to the donor side of the membrane and the methanol transfer to an aqueous acceptor buffer solution.The quantification of the methanol was then achieved in aqueous solution by the combined use of immobilised alcohol oxidase (AOD), soluble peroxidase and 2,2 -azinobis(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS). The optimization of parameters such as the type of membrane, the groove volume and configuration of the membrane unit,the appropriate organic solvent, sample injection volume, as well as immobilised packed AOD reactor was performed. Two dynamic analytical working ranges were achieved, up to 0.015% and up to 0.200% (m/m) methanol concentrations, just by changing the volume of acceptor aqueous solution. Detection limits of 0.0002% (m/m) and 0.007% (m/m) methanol were estimated, respectively. The decision limit (CC ) and the detection capacity (CC ) were 0.206 and 0.211% (m/m), respectively. The developed methodology showed good precision, with a relative standard deviation (R.S.D.) <5.0% (n = 10). Biodiesel samples from different sources were then directly analyzed without any sample pre-treatment. Statistical evaluation showed good compliance, for a 95% confidence level, between the results obtained with the flow system and those furnished by the gas chromatography reference method.The proposed methodology turns out to be more environmental friendly and cost-effective than the reference method.pt_BR
dc.language.isoenpt_BR
dc.sourcehttp://dx.doi.org/10.1016/j.aca.2008.03.005pt_BR
dc.subjectBiodieselpt_BR
dc.subjectMethanolpt_BR
dc.subjectMembrane-based extractionpt_BR
dc.subjectImmobilised enzymept_BR
dc.subjectFlow analysispt_BR
dc.titleFlow methodology for methanol determination in biodiesel exploiting membrane-based extractionpt_BR
dc.title.alternativeAnalytica Chimica ACTApt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 613, n. 2pt_BR
dc.embargo.liftdate10000-01-01-
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
CONFIG~1....0-S0003267008004765-main.pdf
  Restricted Access
150,48 kBAdobe PDFVisualizar/Abrir Solicitar uma cópia
Mostrar registro simples do item Visualizar estatísticas


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.