Skip navigation
Universidade Federal da Bahia |
Repositório Institucional da UFBA
Use este identificador para citar ou linkar para este item: https://repositorio.ufba.br/handle/ri/8208
Registro completo de metadados
Campo DCValorIdioma
dc.contributor.authorJesus, Djane Santiago de-
dc.contributor.authorCassella, Ricardo Jorgensen-
dc.contributor.authorFerreira, Sergio Luis Costa-
dc.contributor.authorCosta, Antonio Celso Spinola-
dc.contributor.authorCarvalho, Marcelo Souza de-
dc.contributor.authorSantelli, Ricardo Erthal-
dc.creatorJesus, Djane Santiago de-
dc.creatorCassella, Ricardo Jorgensen-
dc.creatorFerreira, Sergio Luis Costa-
dc.creatorCosta, Antonio Celso Spinola-
dc.creatorCarvalho, Marcelo Souza de-
dc.creatorSantelli, Ricardo Erthal-
dc.date.accessioned2013-01-29T15:28:21Z-
dc.date.issued1998-
dc.identifier.issn0003-2670-
dc.identifier.urihttp://www.repositorio.ufba.br/ri/handle/ri/8208-
dc.descriptionTexto completo: acesso restrito. p.263–269pt_BR
dc.description.abstractA simple and accurate procedure was developed to preconcentrate and determine zinc in biological matrices. A polyurethane foam (PUF) minicolumn was used for the first time for on-line preconcentration. This system was applied to preconcentrate zinc from aqueous solutions which is sorbed as zinc–thiocyanate complex. Then, the complex was eluted by water and zinc was determined by spectrophotometry using 4-(2-pyridylazo)-resorcinol. The method was validated by the analysis of several biological certified reference materials. The detection limit was 0.9 ng ml−1 and the RSD was 1.2% for 1 min preconcentration time. Generally, concentration of Fe(III), Al(III), Mo(VI), Ni(II), Mn(II), Cu(II), and Co(II) found in biological matrices did not interfere. Dynamic ranges of concentration from 20 to 100 ng ml−1 (1 min preconcentration time) and from 5 to 20 ng ml−1 (5 min preconcentration time) achieve a sample throughput of 20 and 8 samples per hour and a preconcentration factor of 8 and 32, respectively.pt_BR
dc.language.isoenpt_BR
dc.sourcehttp://dx.doi.org/10.1016/S0003-2670(98)00111-1pt_BR
dc.subjectPolyurethane foampt_BR
dc.subjectZinc preconcentrationpt_BR
dc.subjectContinuous flow analysispt_BR
dc.subjectBiological samplespt_BR
dc.titlePolyurethane foam as a sorbent for continuous flow analysis: preconcentration and spectrophotometric determination of zinc in biological materialspt_BR
dc.title.alternativeAnalytica Chimica Actapt_BR
dc.typeArtigo de Periódicopt_BR
dc.identifier.numberv. 366, n. 1-3pt_BR
dc.embargo.liftdate10000-01-01-
Aparece nas coleções:Artigo Publicado em Periódico (Química)

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
de Jesus.pdf
  Restricted Access
123,43 kBAdobe PDFVisualizar/Abrir Solicitar uma cópia
Mostrar registro simples do item Visualizar estatísticas


Os itens no repositório estão protegidos por copyright, com todos os direitos reservados, salvo quando é indicado o contrário.