Campo DC | Valor | Idioma |
dc.contributor.author | Sivin, Irving | - |
dc.contributor.author | Alvarez, Francisco | - |
dc.contributor.author | Diaz, Juan | - |
dc.contributor.author | Diaz, Soledad | - |
dc.contributor.author | Mahgoub, Sayed El | - |
dc.contributor.author | Coutinho, Elsimar Metzker | - |
dc.contributor.author | Brache, Vivian | - |
dc.contributor.author | Diaz, M. Margarita | - |
dc.contributor.author | Faundes, Anibal | - |
dc.contributor.author | Pavez, Margarita | - |
dc.contributor.author | Mattos, Carlos E.R. | - |
dc.contributor.author | Stern, Janet | - |
dc.creator | Sivin, Irving | - |
dc.creator | Alvarez, Francisco | - |
dc.creator | Diaz, Juan | - |
dc.creator | Diaz, Soledad | - |
dc.creator | Mahgoub, Sayed El | - |
dc.creator | Coutinho, Elsimar Metzker | - |
dc.creator | Brache, Vivian | - |
dc.creator | Diaz, M. Margarita | - |
dc.creator | Faundes, Anibal | - |
dc.creator | Pavez, Margarita | - |
dc.creator | Mattos, Carlos E.R. | - |
dc.creator | Stern, Janet | - |
dc.date.accessioned | 2013-02-21T13:23:03Z | - |
dc.date.available | 2013-02-21T13:23:03Z | - |
dc.date.issued | 1984 | - |
dc.identifier.issn | 0010-7824 | - |
dc.identifier.uri | http://www.repositorio.ufba.br/ri/handle/ri/8600 | - |
dc.description | Texto completo. Acesso restrito. p. 443–456 | pt_BR |
dc.description.abstract | Firsty ear resultso f a randomizeds tu% of 1509 usersof the Copper
T38OAg with a silverc ore or of an IUD releasing2 0 mcg day of levonorgestrela
re reported. The cumulativeg ross pregnanq rate for each device
was 0.3 per 100 at one year, with more than 490 wcxnehna vingo ne
year of use with each device. The levonorgestrel-releasidnegv ice was
associatedw ith significantlyf ewer bleeding days and significantly
increasedh emoglobinl evelsw hen ccmparedw ith pre-admissionv alues or
the one year valueso bserveda morrugs erso f the lCu38OAg. 'Itxminations
attributablteo amenorrheaw ere significantlmyo re frequenta mong users
of the levonorgestre-lr eleasingd evice. 'IheT Cu 38OAgw as associated
with increasedf requencya nd severity of dysmenorrheac ompared with
pr~ac%nisaionl evels or with the steroid-releasidnegv ice. Hemoglobin
levelsw ere sanewhatr eduoeda mong userso f the Ku 380Agd evice. I&-
minations attributablet o pain were, however,n ot significantldyi fferentt
y device. Continuatiorna tesa t the end of the firsty ear were
not significantldyi fferentt y device. | pt_BR |
dc.language.iso | en | pt_BR |
dc.publisher | Contraception | pt_BR |
dc.source | http://dx.doi.org/10.1016/0010-7824(84)90036-2 | pt_BR |
dc.title | Intrauterine contraception with copper and with levonorgestrel: A randomized study of the TCu 380Ag and levonorgestrel 20 mcg/day devices | pt_BR |
dc.title.alternative | Contraception | pt_BR |
dc.type | Artigo de Periódico | pt_BR |
dc.description.localpub | Salvador | pt_BR |
dc.identifier.number | v. 30, n. 5 | pt_BR |
Aparece nas coleções: | Artigo Publicado em Periódico (Faculdade de Medicina)
|