Campo DC | Valor | Idioma |
dc.creator | Menezes Junior, José da Natividade | - |
dc.date.accessioned | 2023-02-14T12:50:24Z | - |
dc.date.available | 2023-02-14T12:50:24Z | - |
dc.date.issued | 2022-12-06 | - |
dc.identifier.uri | https://repositorio.ufba.br/handle/ri/36622 | - |
dc.description.abstract | Introdution: Cardiovascular diseases (CVD) are the leading cause of death from chronic
noncommunicable diseases worldwide. Functional performance assessment has been
increasingly used in Intensive Care Units (ICU). Objetive: To verify the functional and
ventilatory performance of individuals with heart disease admitted to the ICU and its
correlation with the left ventricular ejection fraction (LVEF). Method: This is a cross sectional study, carried out at the cardiovascular ICU of the Roberto Santos General Hospital,
in which patients with CVD, who underwent a transthoracic echocardiogram at admission
were submitted to ventilatory function tests, through the assessment of the Maximum
Inspiratory Pressure (MAXIP), Peak Expiratory Flow (PEF) and Functional Performance
Assessment through the 6-Minute Walk Test (6MWT), Gait Speed Test (GST) and 1-Minute
Sit and Stand Test (1min-TSO). The LVEF value were recorded from the medical record.
Results: 111 participants, mostly male (72%), with heart disease, most of them diagnosed
with acute myocardial infarction (75%), had a mean maximum distance walked (6MWD) of
354.6±98, 2m, mean gait speed of 1.32±0.4m/s and at 1min-TSO 18±6.1 repetitions. A
moderate correlation was identified in three functional tests (6MWT vs. TVM, r= 0.51, p
<0.001; 6MWT vs. 1min-TSO, r=0.66, p=0.001 and TVM and 1min-TSO, r=0.51, p<0.001).
Conclusion: There is a weak correlation between the LVEF value and the clinical tests, there
is a moderate correlation between the functional tests in individuals with CDV admitted in
ICU. | pt_BR |
dc.language | por | pt_BR |
dc.publisher | Universidade Federal da Bahia | pt_BR |
dc.rights | CC0 1.0 Universal | * |
dc.rights.uri | http://creativecommons.org/publicdomain/zero/1.0/ | * |
dc.subject | Cardiologia | pt_BR |
dc.subject | Desempenho físico-funcional | pt_BR |
dc.subject | Terapia intensiva | pt_BR |
dc.subject | Fração de ejeção ventricular | pt_BR |
dc.subject.other | Cardiology | pt_BR |
dc.subject.other | Physical functional performance | pt_BR |
dc.subject.other | Intensive care | pt_BR |
dc.subject.other | Physical functional performance | pt_BR |
dc.title | Desempenho funcional de indivíduos com doenças cardiovasculares internados em unidade de terapia intensiva e sua correlação com a fração de ejeção cardíaca | pt_BR |
dc.title.alternative | Functional Performance of Individuals with Cardiovascular Diseases Interned in an Intensive Care Unit and its Correlation with Cardiac Ejection Fraction | pt_BR |
dc.type | Dissertação | pt_BR |
dc.publisher.program | Programa de Pós-Graduação em Processos Interativos dos Órgãos e Sistemas (PPGORGSISTEM) | pt_BR |
dc.publisher.initials | UFBA | pt_BR |
dc.publisher.country | Brasil | pt_BR |
dc.subject.cnpq | CNPQ::CIENCIAS DA SAUDE | pt_BR |
dc.subject.cnpq | CNPQ::CIENCIAS DA SAUDE::FISIOTERAPIA E TERAPIA OCUPACIONAL | pt_BR |
dc.contributor.advisor1 | Correia, Helena França | - |
dc.contributor.advisor1Lattes | http://lattes.cnpq.br/1992245039357469 | pt_BR |
dc.contributor.referee1 | Silva, Cassio Magalhaes da Silva e | - |
dc.contributor.referee1ID | https://orcid.org/0000-0002-9119-5418 | pt_BR |
dc.contributor.referee1Lattes | http://lattes.cnpq.br/0820600663435032 | pt_BR |
dc.contributor.referee2 | Dias, Cristiane Maria Carvalho Costa | - |
dc.contributor.referee2Lattes | http://lattes.cnpq.br/9957165632171725 | pt_BR |
dc.contributor.referee3 | Correia, Helena França | - |
dc.contributor.referee3Lattes | http://lattes.cnpq.br/1992245039357469 | pt_BR |
dc.creator.ID | https://orcid.org/0000-0002-7374-4882 | pt_BR |
dc.creator.Lattes | http://lattes.cnpq.br/9023269667944483 | pt_BR |
dc.description.resumo | Introdução: As doenças cardiovasculares (DCV) são a principal causa de morte por doenças
crônicas não transmissíveis em todo mundo. A avaliação do desempenho funcional tem sido
cada vez mais utilizada nas unidades de terapia intensiva (UTI). Objetivo: Verificar o
desempenho funcional e ventilatório de indivíduos cardiopatas internados em UTI e sua
correlação com a Fração de ejeção do ventículo esquerdo (FEVE). Método: Trata-se de um
estudo transversal, realizado na UTI cardiovascular do Hospital Geral Roberto Santos, no qual
pacientes com DCV foram submetidos aos testes de função respiratória, através da avaliação
da Pressão Inspiratória Máxima (PIMAX), do Pico de Fluxo Expiratório (PFE) e avaliação do
desempenho funcional através do Teste de Caminhada de 6 Minutos (TC6M), Teste de
Velocidade da Marcha (TVM) e Teste de Sentar e Levantar de 1 Minuto (1min-TSO). Os
valores da FEVE foram anotados do prontuário médico. Resultados: 111 participantes,
sendo, em sua maioria, do sexo masculino (72%), indivíduos com DCV, a maioria com
diagnóstico de infarto agudo do miocárdio (75%). Foi observada uma média da distância
percorrida no teste de caminhada de 6 minutos (DTC6) de 354,6±98,2m, velocidade de
marcha média de 1,32±0,4m/s, uma média de 18±6,1 repetições no 1min-TSO, na PIMAX,
obteve-se uma média de -85,2 ±33,4 cmH2O e uma média de 244,5 ±111,0 L/min no PFE.
Foi identificada correlação moderada entre os testes funcionais, (TC6M vs. TVM, r= 0,51,
p<0,001; TC6M vs. 1min-TSO, r=0,66, p= 0,001 e TVM e 1min-TSO, r= 0,51, p<0,001) e foi
observada uma correlação fraca entre a distância percorrida no TC6M e a performance no
1min-TSO e a FEVE (r= 0,42, p<0,001 e r=0,44, p <0,001) e correlação nula entre o TVM e a
FEVE (r=0,22, p=0,001). Conclusão: Há fraca correlação entre o valor da FEVE e os testes
clínicos, e moderada correlação entre os testes funcionais em indivíduos com DCV internados
em UTI | pt_BR |
dc.publisher.department | Instituto de Ciências da Saúde - ICS | pt_BR |
dc.type.degree | Mestrado Acadêmico | pt_BR |
Aparece nas coleções: | Dissertação (PPGPIOS)
|